COMMISSION REGULATION (EU) 2019/2020
of 1 October 2019
laying down ecodesign requirements for light sources and separate control gears pursuant to Directive 2009/125/EC of the European Parliament and of the Council and repealing Commission Regulations (EC) No 244/2009, (EC) No 245/2009 and (EU) No 1194/2012
(Text with EEA relevance)
Article 1
Subject matter and scope
Article 2
Definitions
Article 3
Ecodesign requirements
Article 4
Removal of light sources and separate control gears
Article 5
Conformity assessment
Article 6
Verification procedure for market surveillance purposes
Article 7
Circumvention
Article 8
Indicative benchmarks
Article 9
Review
Article 10
Repeal
Article 11
Entry into force and application
ANNEX I
Definitions applicable for the Annexes
ANNEX II
Ecodesign requirements
1. Energy efficiency requirements:
| 
                                     Light source description  | 
                                 
                                     η  | 
                                 
                                     L  | 
                              
| 
                                     [lm/W]  | 
                                 
                                     [W]  | 
                              |
| 
                                     LFL T5-HE  | 
                                 
                                     98,8  | 
                                 
                                     1,9  | 
                              
| 
                                     LFL T5-HO, 4 000 ≤ Φ ≤ 5 000 lm  | 
                                 
                                     83,0  | 
                                 
                                     1,9  | 
                              
| 
                                     LFL T5-HO, other lm output  | 
                                 
                                     79,0  | 
                                 
                                     1,9  | 
                              
| 
                                     FL T5 circular  | 
                                 
                                     79,0  | 
                                 
                                     1,9  | 
                              
| 
                                     FL T8 (including FL T8 U-shaped)  | 
                                 
                                     89,7  | 
                                 
                                     4,5  | 
                              
| 
                                     From 1 September 2023, for FL T8 of 2-, 4- and 5-foot  | 
                                 
                                     120,0  | 
                                 
                                     1,5  | 
                              
| 
                                     Magnetic induction light source, any length/flux  | 
                                 
                                     70,2  | 
                                 
                                     2,3  | 
                              
| 
                                     CFLni  | 
                                 
                                     70,2  | 
                                 
                                     2,3  | 
                              
| 
                                     FL T9 circular  | 
                                 
                                     71,5  | 
                                 
                                     6,2  | 
                              
| 
                                     HPS single-ended  | 
                                 
                                     88,0  | 
                                 
                                     50,0  | 
                              
| 
                                     HPS double-ended  | 
                                 
                                     78,0  | 
                                 
                                     47,7  | 
                              
| 
                                     MH ≤ 405 W single-ended  | 
                                 
                                     84,5  | 
                                 
                                     7,7  | 
                              
| 
                                     MH > 405 W single-ended  | 
                                 
                                     79,3  | 
                                 
                                     12,3  | 
                              
| 
                                     MH ceramic double-ended  | 
                                 
                                     84,5  | 
                                 
                                     7,7  | 
                              
| 
                                     MH quartz double-ended  | 
                                 
                                     79,3  | 
                                 
                                     12,3  | 
                              
| 
                                     Organic light-emitting diode (OLED)  | 
                                 
                                     65,0  | 
                                 
                                     1,5  | 
                              
| 
                                     Until 1 September 2023: HL G9, G4 and GY6.35  | 
                                 
                                     19,5  | 
                                 
                                     7,7  | 
                              
| 
                                     HL R7s ≤ 2 700 lm  | 
                                 
                                     26,0  | 
                                 
                                     13,0  | 
                              
| 
                                     Other light sources in scope not mentioned above  | 
                                 
                                     120,0  | 
                                 
                                     1,5 (*1)  | 
                              
| 
                                     Light source type  | 
                                 
                                     Basic C value  | 
                              
| 
                                     Non-directional (NDLS) not operating on mains (NMLS)  | 
                                 
                                     1,00  | 
                              
| 
                                     Non-directional (NDLS) operating on mains (MLS)  | 
                                 
                                     1,08  | 
                              
| 
                                     Directional (DLS) not operating on mains (NMLS)  | 
                                 
                                     1,15  | 
                              
| 
                                     Directional (DLS) operating on mains (MLS)  | 
                                 
                                     1,23  | 
                              
| 
                                     Special light source feature  | 
                                 
                                     Bonus on C  | 
                              
| 
                                     FL or HID with CCT > 5 000 K  | 
                                 
                                     +0,10  | 
                              
| 
                                     FL with CRI > 90  | 
                                 
                                     0,10  | 
                              
| 
                                     HID with second envelope  | 
                                 
                                     +0,10  | 
                              
| 
                                     MH NDLS > 405 W with non-clear envelope  | 
                                 
                                     +0,10  | 
                              
| 
                                     DLS with anti-glare shield  | 
                                 
                                     +0,20  | 
                              
| 
                                     Colour-tuneable light source (CTLS)  | 
                                 
                                     +0,10  | 
                              
| 
                                     High luminance light sources (HLLS)  | 
                                 
                                     +0,0058 • Luminance-HLLS - 0,0167  | 
                              
| 
                                     Declared output power of the control gear (Pcg) or declared power of the light source (Pls) in W, as applicable  | 
                                 
                                     Minimum energy efficiency  | 
                              
| 
                                     Control gear for HL light sources  | 
                                 
                                     
  | 
                              
| 
                                     all wattages Pcg  | 
                                 
                                     0,91  | 
                              
| 
                                     Control gear for FL light sources  | 
                                 
                                     
  | 
                              
| 
                                     Pls ≤ 5  | 
                                 
                                     0,71  | 
                              
| 
                                     5 < Pls ≤ 100  | 
                                 
                                     Pls/(2 × √(Pls/36) + 38/36 × Pls+1)  | 
                              
| 
                                     100 < Pls  | 
                                 
                                     0,91  | 
                              
| 
                                     Control gear for HID light sources  | 
                                 
                                     
  | 
                              
| 
                                     Pls ≤ 30  | 
                                 
                                     0,78  | 
                              
| 
                                     30 < Pls ≤ 75  | 
                                 
                                     0,85  | 
                              
| 
                                     75 < Pls ≤ 105  | 
                                 
                                     0,87  | 
                              
| 
                                     105 < Pls ≤ 405  | 
                                 
                                     0,90  | 
                              
| 
                                     405 < Pls  | 
                                 
                                     0,92  | 
                              
| 
                                     Control gear for LED or OLED light sources  | 
                                 
                                     
  | 
                              
| 
                                     all wattages Pcg  | 
                                 
                                     Pcg 0,81 /(1,09 × Pcg 0,81 + 2,10 )  | 
                              
2. Functional requirements
| 
                         Colour rendering  | 
                     
                         CRI ≥ 80 (except for HID with Φuse > 4 klm and for light sources intended for use in outdoor applications, industrial applications or other applications where lighting standards allow a CRI< 80, when a clear indication to this effect is shown on the light source packaging and in all relevant printed and electronic documentation)  | 
                  
| 
                         Displacement factor (DF, cos φ1) at power input Pon for LED and OLED MLS  | 
                     
                         No limit at Pon ≤ 5 W, DF ≥ 0,5 at 5 W < Pon ≤ 10 W, DF ≥ 0,7 at 10 W < Pon ≤ 25 W DF ≥ 0,9 at 25 W < Pon  | 
                  
| 
                         Lumen maintenance factor (for LED and OLED)  | 
                     
                         The lumen maintenance factor XLMF% after endurance testing according to Annex V shall be at least XLMF,MIN % calculated as follows: [Bild bitte in Originalquelle ansehen] where L70 is the declared L70B50 lifetime (in hours) If the calculated value for XLMF,MIN exceeds 96,0 %, an XLMF,MIN value of 96,0 % shall be used  | 
                  
| 
                         Survival factor (for LED and OLED)  | 
                     
                         Light sources should be operational as specified in row ‘Survival factor (for LED and OLED)’ of Annex IV, Table 6, following the endurance testing given in Annex V.  | 
                  
| 
                         Colour consistency for LED and OLED light sources  | 
                     
                         Variation of chromaticity coordinates within a six-step MacAdam ellipse or less.  | 
                  
| 
                         Flicker for LED and OLED MLS  | 
                     
                         Pst LM ≤ 1,0 at full-load  | 
                  
| 
                         Stroboscopic effect for LED and OLED MLS  | 
                     
                         SVM ≤ 0,4 at full-load (except for HID with Φuse > 4 klm and for light sources intended for use in outdoor applications, industrial applications or other applications where lighting standards allow a CRI< 80)  | 
                  
3. Information requirements
ANNEX III
Exemptions
| 
                                        Blue  | 
                                    
                                        440nm — 490nm  | 
                                    
                                        90 %  | 
                                 
| 
                                        Green  | 
                                    
                                        520nm — 570nm  | 
                                    
                                        65 %  | 
                                 
| 
                                        Red  | 
                                    
                                        610nm — 670nm  | 
                                    
                                        95 %  | 
                                 
ANNEX IV
Verification procedure for market surveillance purposes
| 
                         Parameter  | 
                     
                         Sample size  | 
                     
                         Verification tolerances  | 
                  
| 
                         Full-load on-mode power Pon [W]:  | 
                     
                         
  | 
                     
                         
  | 
                  
| 
                         Pon ≤ 2W  | 
                     
                         10  | 
                     
                         The determined value shall not exceed the declared value by more than 0,20 W.  | 
                  
| 
                         2W < Pon ≤ 5W  | 
                     
                         10  | 
                     
                         The determined value shall not exceed the declared value by more than 10 %.  | 
                  
| 
                         5W < Pon ≤ 25W  | 
                     
                         10  | 
                     
                         The determined value shall not exceed the declared value by more than 5 %.  | 
                  
| 
                         25W < Pon ≤ 100W  | 
                     
                         10  | 
                     
                         The determined value shall not exceed the declared value by more than 5 %.  | 
                  
| 
                         100W < Pon  | 
                     
                         10  | 
                     
                         The determined value shall not exceed the declared value by more than 2,5 %.  | 
                  
| 
                         Displacement factor [0-1]  | 
                     
                         10  | 
                     
                         The determined value shall not be less than the declared value minus 0,1 units.  | 
                  
| 
                         Useful luminous flux Φuse [lm]  | 
                     
                         10  | 
                     
                         The determined value shall not be less than the declared value minus 10 %.  | 
                  
| 
                         No-load power Pno, Standby power Psb and Networked standby power Pnet [W]  | 
                     
                         10  | 
                     
                         The determined value shall not exceed the declared value by more than 0,10 W.  | 
                  
| 
                         CRI [0-100]  | 
                     
                         10  | 
                     
                         The determined value shall not be less than the declared value by more than 2,0 units.  | 
                  
| 
                         Flicker [Pst LM] and stroboscopic effect [SVM]  | 
                     
                         10  | 
                     
                         The determined value shall not exceed the declared value by more than 10 %.  | 
                  
| 
                         Colour consistency [MacAdam ellips steps]  | 
                     
                         10  | 
                     
                         The determined number of steps shall not exceed the declared number of steps. The centre of the MacAdam ellipse shall be the centre declared by the supplier with a tolerance of 0,005 units.  | 
                  
| 
                         Beam angle (degrees)  | 
                     
                         10  | 
                     
                         The determined value shall not deviate from the declared value by more than 25 %.  | 
                  
| 
                         Control gear efficiency [0-1]  | 
                     
                         3  | 
                     
                         The determined value shall not be less than the declared value minus 0,05 units.  | 
                  
| 
                         Lumen maintenance factor (for LED and OLED)  | 
                     
                         10  | 
                     
                         The determined XLMF% of the sample following the test in Annex V of this Regulation shall not be less than XLMF, MIN%(1).  | 
                  
| 
                         Survival factor (for LED and OLED)  | 
                     
                         10  | 
                     
                         At least 9 light sources of the test sample must be operational after completing the test in Annex V of this Regulation.  | 
                  
| 
                         Excitation purity [%]  | 
                     
                         10  | 
                     
                         The determined value shall not be less than the declared value minus 5 %.  | 
                  
| 
                         Correlated colour temperature [K]  | 
                     
                         10  | 
                     
                         The determined value shall not deviate from the declared value by more than 10 %.  |